BIOCHEMISTRY ANALYSERS

MODEL BA-D200A
Adopt imported concave raster as dispersion element with adjustable wavelength, little error of wavelength, high optics performance and nonadjustable computer drive raster. 
Inner microcomputer control & spectroscopic data processing;
Automatic printing, automatic storage, automatic wavelength setting, real time screen display.
Be tested with application performance rate method, two point method, linear end-point method, nonlinear end-point method, absorbency method, sample blank method, single & double wavelength method.
Open program with 200 biochemical items & choice reagent. 

 
New storage method,   can store item parameter & results permanently after power cuts.
Wavelength Range: 330-800nm
Absorbency Measuring Range : 0.3-3.0Abs
Cross Contamination: 1%
Temperature Control: 25°C, 30°C, 37°Cor room temperature
Display: liquid crystal Chinese display
Keyboard: 16 Keys Film Light-touch Key
Printer: inner wide-row high-speed thermal printer c
Interface: Standard RS-232C Interface

MODEL BA 2018G
Wavelength Range - 340nm~750nm
Measurement Range - 0.001~3.000Abs
Repeatability - ≤0.005Abs
Linearity - ≤±1%

 
Cross-contamination - ≤1%
Temperature Accuracy - ±0.2°C
Test Method - Absorbency, End-point, Kinetic, Two-point, Standard Curve, Control Tube, Factor.
Colorimetric Pool - Titanium alloy
Display - Touch-screen

MODEL BA-6008
Type: Fully automated,   clinical chemistry analyzer
Throughput: 130 tests / hour,   up to 200 tests / hour
Test Mode: End point,   Fixed time (two point),   Kinetics (velocity),   Immuno assays; Monochromatic,   Bi-chromatic & Multi-chromatic; Linearity & Nonlinearity, Single / Dual Reagents,   Monochromatic / Bi-chromatic testing.
Test Range: Clinical Biochemistry,   Specific protein,   ISE,   Therapeutic medicine,   Drug abuse,   Urine/ Cerebrospinal fluid,   etc.
Sample tray: 28 sample positions,   any position can be aligned as STAT which can be inserted at any time during the routine examination.
Sample volume: 2µl~35µl,   programmed in 0.1µl step
Reagent tray: 56 reagent positions for R1 and R2
Refrigeration: 24 hours non-stop cooling with Peltier element maintaining temperature 4~15°C

 
Probe Cleaning: inner and outer wall auto washing with warm water,   carry over < 0.1%
Reaction tray: 48 reaction corvettes,   6mm optical path,   plastic corvette,   semi-permanent
Reaction volume: 150µl ~300µl
Reaction time: about 10 minutes
Temperature: 37°C,   fluctuation + 0.1°C
Light source: Halogen lamp,   6V/10W,   life span ≥ 3000 hours
Wavelength: 340nm,   405nm,   450nm,   492nm,   505nm,   546nm,   578nm,   620nm,   670nm, 700nm
Absorbance range: 0.000 Abs ~3.000 Abs - Resolution: 0.001Abs
Calibration mode: Linear (one-point,   two-point and multi-point), Logit-Log4P,   Logit-Log5P,   Spline curve,   Exponential  function,   Polynomial,   Parabola
QC rules: Westgard Multi-rule,   Cumulative Sum Check,   Twin Plot,   3 concentration levels QC
QC mode: Real time,   Intra day & Inter day QC